FT-50 Fill Level Inspector Service Manual
8-8
Error Number 48
The AC input voltage dropped below 90 volts on a 110 VAC system
or below 185 volts on a 220 VAC system. During the time the
voltage was low, no containers were inspected for any defect.
When the power returns to normal, the system resets with no data
being lost. This is a high priority error condition and will cause the
Warning Beacon to flash if Beacon Status is set to HIGH PRIORITY
ONLY.
Error Number 49
The User Defaults loaded for one or more settings are out of range.
Check all settings to be sure they are correct.
This is a high priority error condition and will cause the Warning
Beacon to flash if Beacon Status is set to HIGH PRIORITY ONLY.
Error Number 50
The System defaults loaded for one or more settings are out of
range. A complete software setup must be performed.
This is a high priority error condition and will cause the Warning
Beacon to flash if Beacon Status is set to HIGH PRIORITY ONLY.
Error Number 51
A container passed without any encoder pulses. This can be
caused by:
blocking the trigger with the line stopped
encoder failure
trigger reflections
line jams
Check the gain on the trigger amplifier.
This error condition is low priority and will not cause the Warning
Beacon to flash during HIGH PRIORITY ONLY operation.