Chapter 8: Diagnostic and Repair Procedures
8-19
There is no display except for blinking cursor and the beacon is
solid.
1. Check to be sure the reset switch is not stuck.
2. Check to be sure all PROMs on the processor card are seated
properly.
3. Replace the processor card.
There is no Display and the beacon is off.
1. If you are using a remote control panel check that it is plugged
into the connector on the inspection head correctly.
2. Reset the FT-50 by pressing the Reset Button for three seconds
while turning the machine off and on.
If the beacon does not flash, replace the beacon bulb and
test again.
If the beacon is solid there is a problem with the processor
card.
If the beacon flashes once and stops, there is a problem
with the terminal card.
The display is garbled or operates erratically:
1. Replace the processor card.
2. Replace the terminal card.