Chapter 4: Configuring the FT-50 for Operation
4-11
3. Find your type of missing lid sensor in the table below and
adjust the upper jam nut to raise or lower the sensor to the
proper height.
4. When you achieve the proper height, tighten the lower jam nut
to secure the sensor positioning.
5. If you will not be performing further alignment procedures,
open the safety shutter by pulling the actuating rod out until it
stops.
Sensor Description (Lid Type) Maximum Height Above Lid
21242 Nonferrous (Aluminum) 0.4 inch (10 mm)
21856 Photo-Optic Sensor (All) 0.7 inch (18 mm)
24596 Extended Range (Aluminum)
Extended Range (Steel)
0.5 inch (13 mm)
0.88 inch (22 mm)
91098 Standard 0.25-0.38 inch (6-9 mm)