FT-50 Fill Level Inspector Service Manual
4-18
8. Use the following equation to determine the Looktime Gate in
milliseconds.
9. Press Key 1 until you reach LOOKTIME GATE and use the
Arrow Key to enter the Looktime Gate Value you calculated.
10. If you are finished configuring the FT-50, press Key 5 until you
reach SYSTEM DISPLAY and then press the Arrow Key to
return to the Operate Mode.
where:
D = Average Time Width of Can (step 7).
L = Looktime gate in milliseconds.
D 0.6×()L=