Display panel buttons
Button To Do this
View the software version, operating hours
(h), and switching cycles (c).
Press and hold the P1 button for five
seconds.
Release pressure from the vessel. Press the P2 button.
Set the cycle counter to zero. Press and hold the P3 button for five
seconds.
Switch the potential free contacts for a
warning message from N/O to N/C. You can
accept the selected signal in the ADS and use
it there for an additional alarm or as a way to
stop the cutting process.
Press and hold the P4 button for 10
seconds.
ALT No functionality. —
DEL No functionality. —
ESC No functionality. —
OK Functional from the "Running" screen only. Password: Functionality disabled.
Stop/Run: A check mark show what
state the unit is in. Press the OK button
to toggle between states. When you
switch from Run=>Stop, the pressure
vessel depressurizes.
Password: Appears twice in menu, but
functionality is disabled.
Info: Displays information about the
PLC from the manufacturer.
Set clock: Sets the correct time and
date for the PLC; however, this is
unnecessary for operation as the unit
counts relative time from a "zero" point.
© 2021 Flow International Corp.
Retrieved from Flow KB on April 14, 2021 PST
Ancillary option: PASER CF900 Abrasive Delivery System