Replace the PV1 pinch valve seal
Recommended maintenance interval
Replace the PV1 pinch valve seal after approximately 6000 switching cycles.
Parts
Pinch valve seal (hose insert) …………… A-31850-1
Tools
Adjustable wrenches: 6 in. & 12 in.
Supplies
Clean, lint-free rag
Wooden blocking
Notes
= Assistant required for this step.
Safety precaution
The vessel could weigh up to 91 kg (200 lb) when full. Support the vessel if it is not empty.