Facility requirements · Mach 300
Clearances
All models
Recommended clearance each side ……………………1000 mm (39 in.)
Minimum vertical clearance, unobstructed …………………… 3810 mm (150 in.)
Electrical
Electrical
Power supply …………… 3-phase
Voltage/frequency …………… 480 VAC/60 Hz or 400 VAC/50 Hz
Main circuit breaker size
*
…………… 20 amp
* For machine only; does not include the high-pressure pump.
Ethernet connection
The maximum cable length for Ethernet connection is 76 m (250 ft). If a longer length of cable is
required, you must install a switch near the interface enclosure to amplify the signal. Otherwise, it may
not be possible to connect the machine to your network, and this will limit our ability to support the
machine via VPN.