EasyManua.ls Logo

Flow MACH 300 - Lubricate the bearings and linear rails · (A)

Flow MACH 300
185 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lubricate the bearings and linear rails · (A)
Where used
Mach 500 · Mach 300
Recommended maintenance interval
Every 120 hours of operation
Good to know!
Z-axis rails do not require lubrication.
Tools
Hex key
MG70 grease gun (supplied with machine)
Phillips screwdriver
Supplies
AFF Grease cartridge · A-31748-1
Clean, lint-free cloth
Sheet of plywood
Grease points
View: User faces the front of the machine.
X-axis bearings ……………… Bridge, rear side, center
X-axis ball nut ……………… Motor drives enclosure, rear side
V-axis bearings ……………… Left riser, rear side
V-axis ball nut ……………… Left base rail
Y-axis bearings ……………… Right riser, rear side
Y-axis ball nut ……………… Right base rail
Z-axis ball nut ……………… Z-axis enclosure
© 2021 Flow International Corp.
Retrieved from Flow KB on April 15, 2021 PST
Bellows, bearings, and linear rails maintenance