FortiAnalyzer Version 3.0 MR3 Administration Guide
56 05-30003-0082-20060925
Configuring the FortiAnalyzer unit Configure the FortiAnalyzer unit
Figure 18: FortiAnalyzer-2000 RAID settings
Enable RAID Select to enable RAID 5. To enable other RAID levels, use the
command line interface. For command details see the
FortiAnalyzer CLI Reference.
Enable Hot Spare Select to enable the use of a hot spare with the RAID array.
Additional RAID levels are set in the CLI.
Total Disk Space The amount of disk space available within the RAID array.
Available Disk Space The amount of free disk space.
Click to start
controller rescan
Select after removing or adding a hard disk to the unit. This
enables the FortiAnalyzer unit to update the status of the hard disk
configurations.
Unit The hard disk grouping.
Type The setting for the unit. When employing a RAID level that
includes a hot spare, the hard disk assigned as a hot spare
appears as a separate unit.
Status The status of the unit. For example, when starting a RAID array,
“Initializing” appears. When the hard disk if functioning normally,
“OK” appears.
Size The total size of the unit for the RAID level or the size of the spare
hard disk.
Port The hard disk number.
Part of Unit Indicates if the hard disk is a part of the RAID array.
Status The current state of the hard disk.
Size (GB) The size of the hard disk.
Remove / Add To change a failed hard disk, select Remove to inform the
FortiAnalyzer unit that the hard disk will be removed. After
removing, the selection will become Add. Once the hard disk is
replaced, select Add.
For details on hot swapping hard disks, see “Hot swapping the
FortiAnalyzer-2000 and FortiAnalyzer-4000/4000A” on page 62.