43
Integral cooling
unit
Rating plate
The cooling capacity of a cooling unit depends on:
- Pump type
- Ambient temperature
- Delivery head
- Flow rate Q (l/min)
- The ow rate Q depends on the length of the hosepack and the diameter of the hose.
Supply voltage 1 x 230 V
Mains frequency 50 / 60 Hz
Fuse protection 16 A slow-bow
Current input 1,3 A
Feed rate (Q
max
)
max. 3,0 l / min
Cooling capacity at 40°C / 104°F 1l / min 500 W
1706 BTU / h
Delivery head max. 30 m
max. 98 ft. 5 in.
Pump pressure max. 4,3 bar
max. 62.37 psi
Pump type Centrifugal pump
Coolant capacity 1,8 l
P1l/min
500 W
4.3 bar (0.43 MPa)
I1 effI1 max
230 V 23 A 14 A16A
U1
1~
50-60Hz
35%
145 A
5 A / 10.2 V - 200 A / 18.0 V
200
10 A
15.8 V 14.4 V18.0 V
I2
U2
U0
X(40°C) 60% 100%
44 V
9.5 kV
U
p
IP 23
IEC 60974-1/-10 Cl.A
f1
f2
f1
f2
1~
FPA 3020
8,040,098
XXXXXXXX
Ser.No.
Part No.
www.fronius.com