33
- Number appearing next to
„POSITIONING“ is the time elapsed
since welding started
- Seg 1
status indicator for current segment
- Pos
position of the orbital welding gun [°]
- Spd
welding speed [cm/min]
- Cur
welding current [A]
- Volt
welding voltage [V]
- Date and time
- Orbital welding gun type
- Start --> CONTINUE
press Start/ Stop to start welding
- Stop --> BREAK
press Stop to stop welding immediately
- Pos:
position of the orbital welding gun [°] /
welding speed [cm/min]
- Seg 1
status indicator for current segment
IMPORTANT! If the „ROLL-UP“ parameter in dialog window 221 „Parameters for start
point“ (see „Parameter settings“) is set to „AUTOSTART“, the system goes straight from
positioning to gas pre-ow.
If ller wire is available and activated while the orbital welding gun is open, then the
„Wire Real Value“ also appears for the wire feed speed [cm/min]
Display idle
Display during
gas preow
Display after
welding starts, if
positioning takes
place
Display after
positioning and
before gas pre-
ow
- Date and time
- Name of the currently loaded welding
program
- Orbital welding gun type
- READY/NOT READY - power source
ready to weld, or error needs to be
rectied
- Seg 1
status indicator for current segment
- Pos - position of the orbital welding gun
[°] / welding speed [cm/min]
- Wire feed speed [cm/min]
- Number appearing next to
„GAS PREFL.“ is the elapsed time
since welding started
- Seg 1
status indicator for current segment
- Pos
position of the orbital welding gun [°]
- Spd
welding speed [cm/min]
- Cur
welding current [A]
- Volt
welding voltage [V]
FCH-6-76
READY
Pos 0/
Wirespeed
Seg 1
0.0
0
04.12.15 10:20:57
CrNi_40.0x1.5
Pos/D
Speed
Curr
Volt
0
0.0
0
0.0
Seg 1
cm/min
A
V
POSITIONING 12.0
FCH-6-76
Start--> CONT.
Stop --> BREAK
Pos 0 / 0.0
Seg 1
04.12.15 10:20:57
Pos/D
Speed
Curr
Volt
0
0.0
0
0.0
Seg 1
cm/min
A
V
GAS-PREFLOW 6.0