Logging on a
different user,
and changing the
password
To call up a different pre-saved user
in order to log him on under his name,
touch the „USER ++“ button.
If the password of the user that has just
been logged on is to be changed:
1. Touch button (1)
2. Further details can be found in the
section headed “Changing pass-
word”
To assign user permissions:
3. Touch „EDIT USER“ button (2)
4. Further details can be found in the section headed “User permissions”
IMPORTANT! Only an administrator is authorised to assign user permissions. If a
user’s details have been changed, the user can no longer log on using his original
user details.
To protect the power source from parameter changes:
5. Lock the power source by touching the padlock symbol (3)
IMPORTANT! The power source goes immediately into “Locked” status and only
the actual welding mode is supported. You cannot change any settings.
To unlock the power source:
6. Touch the padlock symbol (3) again.
7. Click on the request to enter the password. Once the keypad appears, type in the
password.
8. Press „>>“ to call up the settings for User-specic settings
(1)
(2)
(3)
Provide the following information:
1. Language currently selected
select the desired language
2. F1
select a function that has been de-
ned for the F1 key by the user
3. F2
select a function that has been de-
ned by the user for the F2 key on
the remote control unit
4. APPLY:
if “With Conrmation” is selected,
a warning prompt is displayed
before data is overwritten.
5. The following user-dened functions are available for the keys:
- No function
- Active alarm page
- Alarm history
- Move to starting position
- Save screenshot to USB
- Water pump OFF/ON
- Load next program
6. Press „>>“ to call up the settings for brightness and contrast