84
Retrieving alarm
list
(continued)
The following actions can be performed
from the tray screen:
- Open the active alarm page by touch-
ing the „Alarmlist“ button
IMPORTANT! For more detailed infor-
mation on the alarms, please refer to the
section headed “Alarms and error
messages”.
- Press the „Acknowledge“ button to reset all alarms
- Press „Clockwise“ or „Counterclockwise“ to enter the welding direction
- Press the „Welding on“ button to start a test (without arc or shielding/forming gas)
- Press the “Wire on” button to enable or disable wire feeding
- Press the „Left“ or „Right“ button to advance or retract the wire
- Press the „Left“ or „Right“ button to move the orbital welding gun in the desired
direction
Alarms and error
messages
Group 001
001 Alarms are bypassed
002 Internal connection problem
Internal communication problem in
the processors
003 Gateway Timeout
Faulty connection to the gateway
004 USB
Problem retrieving data from USB
stick
005 Low Gas Pressure
Alarm for shielding gas monitor
006 Power supply
Power supply alarm
007 Weldhead error
Motor controller error
008 Wire error
Motor controller error
009 Emergency Stop activated
The emergency stop button has activated a safety cut-out
--- SA Internal alarm
Alarm as per plain text display