68
Provide the following information:
1. Screensaver Time
time until the touchscreen goes off,
counted down from the previous
operation [min:s]
If set to OFF, the display goes off
after two hours.2.
2. Seam number
alloca- tion of a number for the cur-
rently active weld seam
3.
Password On / Start
► OPEN - the user last logged on is automatically logged on once the power
source is switched on, without the need to provide a password
► PWD INPUT - a password is requested when the power source is switched on.
► LOCKED - when the power source is switched on, no password is requested
the power source goes immediately into „Locked“ status and only the actual
welding mode is supported. You cannot change any settings. To unlock, please
see the section headed „Logging on a different user and changing the pass-
word“
4. Auto Reset Energy
- If “Autoreset energy” active, the energy is automatically deleted at the start of a
new weld.
- If “Autoreset energy” inactive, the energy is to be deleted manually (by press-
ing the Stop button) at the start of a new weld.> Multilayer welds with different
programs can be realized.
5. Touch button “Fronius-Automation”(a)
to bring up a keypad for entering text
6. Use the „ROTATION“ button to call up the window for the rotation and welding
speed parameters.
The following values allow you to
provide the step width and the maximum
value:
1. Welding current [A]
2. v-Rotation
rotation speed of orbital welding
gun [cm/min]
3. WFS
wire feed speed [cm/min]
4. Use the “>>” button to open the
“More Parameters” window
IMPORTANT! The values are not active if the „PAR. FINDER“ and „ADMIN“ user
permissions are selected. More detailed information on the user settings can be found in
the „User settings“ section
Value adjustment
More parameters
(a)