1. START
to start the welding process.
2. STOP
to nish the welding, with down-
slope
IMPORTANT! If welding has to be
stopped immediately, for safety reasons
for example:
- Click the ABORT button.
Welding stops immediately, with gas
post-ow but no downslope
IMPORTANT! If the „not ready“ message appears in the window, touch the text; the next
window shows the problematic status.
The following parameters appear:
Totaltime: Running time since the start of the current welding program [min].
Sector: Actual runtime for the present welding section [min]
IMPORTANT! A new welding section begins after every event
- e.g. gas pre-ow or moving to start point.
Position: Position of the electrode [degrees]
v- Weld: Welding speed [cm/min]
The following elds appear:
(a) Actual welding current [A]
(b) Actual welding voltage [V]
(c) Seam number
IMPORTANT! The seam number is also part of the le name
when the actual value is recorded. If the seam number is high-
lighted in orange, the value displayed indicates the number of the
currently welded tacking point.
(d) Welding energy [kJ]
With button (e), call up the “welding process status” window.
Green font: “Welding energy OK”:
measured welding energy is in permitted
range
Red font: “Welding energy fail”:
measured welding energy has exceeded
the higher limit or underrun the lower limit
Welding energy
status
By pressing the STOP button 2x on the remote control, the value will be reset.