Group 004 (continued)
Group 005
001 Weldhead no movement
No rotation taking place, despite a
command being sent
002 Wire feed unit
Wire not being transported,
despite a command being sent
003 Motor.Curr.Weldhead
The analog entry value for the
motor current is too high. Check
rotation.
004 IR: Emergency pressed
The emergency stop button has activated a safety cut-out
005 IR Stop key -> interrupt
Welding was interrupted by the Stop button
006 IR Alarm (see alarm page)
Miscellaneous alarm
007 IR Arc w/o main current signal
Main current signal missing
008 IR No arc signal
Arc OK signal missing
009 IR Start key -> H(21)
Start button -> Halt is active
--- SA Weld manager
Alarm as per plain text display
004 Motor.curr.wire
The analog entry value for the motor current is too high. Check wire-feed unit.
005 Oxygen Alarm
Residual oxygen measuring device measures residual oxygen at the welding
location.The input is active and an alarm occurs.
006 Print on USB problem
A problem has occurred while printing as a le to the USB stick. Check USB stick
or change the printout parameters.
007 OSC Stepper drive problem 0
see Servo controller error list
008 AVC Stepper drive problem 0
see Servo controller error list
009 AVC T&R Timeout
T&R function has timed out. Cause: earth not connected on workpiece; work-
piece is very dirty.
--- SA Internal alarm
Alarm as per plain text display