CHAPTER 3
Small Configuration
Installing Fans
3-83
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
3.15 Installing Fans
This procedure provides installation instructions for the four cooling fans used by the
Optical/Tributary shelf (see Figure 3-70 [p. 3-83]).
1 If not already done, unpack four fan plug-in units from the shipping container.
2 If not already done, install a fan filter in the fan tray located at the bottom of each fan unit.
3 Install the fan plug-in units into the bottom portion of each Optical/Tributary shelf. (Refer to
Section 8.8, Replacing FAN6 Plug-In Unit and Fan Filter [p. 8-28] for a detailed
information.)
Note: The connectors on the back of the fan engage the shelf backplane connectors and are secured
in place with an extractor lever (located on the left side of the fan assembly front panel).
This procedure is complete.
Figure 3-70: Fan Unit (Front View)
(Small Configuration)
FAN6
FAIL/SVCE
FC9682FAN6
Iss. 01
m1656wy_1