4.16.7 Installing RICC Cable (Optical Shelf)
This procedure provides instructions for connecting to the RICC ports on the Optical shelf.
RICC port connectors are located in the station interface area (SIA) at the top front of the
ETSI Optical shelf (SHU4).Table 4-7 [p. 4-85] lists pertinent information for these cables.
Figure 4-56 [p. 4-85] shows the cable connector pinouts.
Note: The RICC cable is only required for HUB configurations.
Step Task
1 Connect the RJ-45 connector on one end of the RICC cable (21-332-xxx) to connector
CN24, CN25, CN31, or CN32 in the SIA of the Main Optical shelf.
2 Connect the other end of the RICC cable to the appropriate Auxiliary Optical shelf connector
indicated in Table 4-8 [p. 4-86].
Table 4-7: LAN Cable Information (ETSI Configuration)
Cable Part
Number
Connector Number
Cable
Description
Connector
Type
Cable Wire
Size
21-332-xxx
a
a
xxx = length in feet
CN24, CN25, CN31, and
CN32 (Main and Auxiliary
Optical shelves)
RICC
connection
RJ-45 24 AWG
Figure 4-56: Connector Pinouts, RICC Cable
1
2
3
4
5
6
7
8
TXP
TXN
RXP
RXN
m1714au_1