CHAPTER 4
ETSI Configuration
Installing Cables
FNC-7500-0061-200
Issue 1, May 2009
FLASHWAVE 7500 Release 6.1
Equipment Installation
4-82
Fujitsu and Fujitsu Customer Use Only
4.16.6 Installing LAN Cable (Optical/Tributary Shelf)
This procedure provides instructions for connecting to the LAN ports of the Optical and
Tributary shelves. LAN port connectors are located in the station interface area (SIA) at the
top front of the ETSI Optical/Tributary shelf (SHU4). Table 4-5 [p. 4-82] lists pertinent
information for these cables. Figure 4-54 [p. 4-82] shows the cable connector pinouts.
1 Connect the RJ-45 connector on one end of the LAN cable (21-332-xxx) to the primary
Tributary shelf or Auxiliary Optical shelf connector CN1.
Table 4-5: LAN Cable Information (ETSI Configuration)
Cable Part
Number
Connector Number
Cable
Description
Connector
Type
Cable Wire
Size
21-332-xxx
a
a
xxx = length in feet
For the Optical shelf:
CN2, CN6
LAN
connection
RJ-45 24 AWG
For Tributary shelves:
CN1, CN3
Figure 4-54: Connector Pinouts, LAN Cable
1
2
3
4
5
6
7
8
TXP
TXN
RXP
RXN
m1714au_1