CHAPTER 4
ETSI Configuration
Installing the Optical/Tributary Shelf
4-25
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
4.8 Installing the Optical/Tributary Shelf
The FLASHWAVE 7500 ETSI Configuration system is based upon the ETSI shelf
(FC9682SHU4), which can be configured as either an Optical or a Tributary shelf.
The ETSI rack must already be installed in accordance with local plans and procedures.
Figure 4-10 [p. 4-26] shows the Optical and Tributary shelf mounting in the ETSI rack.
Figures 4-11 [p. 4-27] and 4-12 [p. 4-28] show front views of the Optical shelf and the
Tributary shelf for reference.
Note: Figures 4-11 [p. 4-27] and 4-12 [p. 4-28] are shown fully populated for instructional
purposes. At installation, the shelves do not have plug-in units installed. The shelves are not
populated and provisioned until system turn-up.
Note: The FLASHWAVE 7500 shelves do not have front covers because of front-access fiber
cabling.
DANGER:
Do not attempt to handle and install the shelves without sufficient assistance. The
Optical/Tributary shelf weighs approximately 48.5 lb (22 kg) empty (without fans).
Equipped, the Optical/Tributary shelf weighs significantly more. Handling the equipment
without sufficient assistance may result in personal injury, damage to the equipment, or
both.
WARNING:
Do not use the internal walls of any shelf as a lifting point or lift support. Doing so may
damage the plug-in unit rail support.
CAUTION:
Do not compromise the stability of the rack when installing this equipment. Unstable racks
can fall resulting in equipment damage.