EasyManua.ls Logo

Fujitsu FLASHWAVE 7500 - 2.13 Installing Cables

Fujitsu FLASHWAVE 7500
392 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 2
Core Configuration
Installing Power, Ground, and Alarm Cables
FNC-7500-0061-200
Issue 1, May 2009
FLASHWAVE 7500 Release 6.1
Equipment Installation
2-44
Fujitsu and Fujitsu Customer Use Only
Figure 2-27: Optical/Tributary Shelf Power Cabling
(Core Configuration)
Wiring Diagram
Cable Diagram
FLASHWAVE 7500 Backplane
Application
Support Part No.: HA15B-0001-C413
FNC Mfg. Part No.: HA15B-0001-C413
Power Cable Assembly
FLASHWAVE 7500
Backplane
FNC Customer
Circuit Breaker Panel
Notes:
The connections to the FLASHWAVE 7500 backplane are screw
terminations at the power terminal. The cable assembly shown here
provides -48 V DC battery (MAIN A, MAIN B), battery return (GA, GB), and
frame ground (FG).
MAIN A
MAIN B
GA
GB
FG
-48 V DC A
GA
-48 V DC B
GB
RACK
RED
RED
BLK
BLK
GRN
Lug, 1/4 in.
his end terminated
at FLASHWAVE
7500 shelf.
Lug, No. 10
This end
terminated at
HA15B-0001-B361
Circuit Breaker Panel.
Bagged Together
MAIN A
GA
MAIN B
GB
FG
10 AWG RED
10 AWG BLK
10 AWG RED
10 AWG BLK
10 AWG GRN
PWR HARN
G AG B FG MAIN B MAIN A
Part
Numbers
12 ft
m1656xd_5
Revision 1, June 2009

Table of Contents

Related product manuals