CHAPTER 2
Core Configuration
Installing Cables
FNC-7500-0061-200
Issue 1, May 2009
FLASHWAVE 7500 Release 6.1
Equipment Installation
2-68
Fujitsu and Fujitsu Customer Use Only
Step Task
1 If not already installed, refer to Section 2.10 [p. 2-36] to install the alarm cable. See
Figure 2-21 [p. 2-38] for cable assembly drawings and Figures 2-22 [p. 2-39] through 2-24
[p. 2-41] for power, ground, and alarm cabling diagrams.
2 Ensure that backplane alarm connector CN42 of the Optical/Tributary shelves (see
Figure 2-33 [p. 2-61]) is connected to a shelf cable assembly that terminates into one of the
rack alarm cable harness connectors (CNA through CNF, Figures 2-22 [p. 2-39]
through 2-24 [p. 2-41]).
3 The end of the multiconnector, rack alarm cable assembly (not terminated and
nonconnectorized) is wire wrapped to the local office alarm facilities or at the CBP alarm
termination block. Refer to Cable and Wiring Guide, for wire-wrap color code details and
Circuit Breaker Panel, for CBP alarm block details.
This procedure is complete.
Figure 2-37: Connector Pinouts, Alarm Cable
































Revision 1, June 2009