CHAPTER 2
Core Configuration
Installing Cables
2-71
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
2 Connect the other end of the LAN cable to the appropriate Main Optical shelf backplane
connector (CN6, CN7, CN19…CN23), Auxiliary Optical shelf backplane connector
(CN19…CN22), or Tributary shelf backplane connector (CN19 or CN20) as indicated in
Figure 2-40 [p. 2-72] and Table 2-8 [p. 2-73].
Note: If the node is an asymmetric HUB node (Keyword HUBMODE=MANUAL in the ED-SYS
command), the system can include two additional shelves (Optical shelves OS25 and OS26) shown in
Figure 2-40 [p. 2-72]. Both connect to shelf OS2 in the hierarchy of LAN connections but do not
support subtending Tributary shelves.
3 Proceed to Section 2.13.9, Installing RICC Cable (Optical Shelf) [p. 2-75], if RICC cables
are required.
This procedure is complete.