251
PRIMERGY RX300 S4 User's Guide
C Remote Control Function
This server supports a remote control function.
When a personal computer (PC) is connected to the serial port of this server with an
RS-232C cross cable, the PC can be used to control (turn on/off and reset) the server
power supply (remote control).
C.1 Preparation for Using Remote Control Function
To enable the remote control function, perform the procedures in the following sections.
Configuring the BIOS
Connecting the Server to a PC
Configuring the Terminal Software (PC)
Configuring the BIOS
To use the function of the server management port, perform the following setting using the BIOS Setup
Utility.
1 Turn on the server. Press the [F2] key during POST to start up the BIOS Setup
Utility.
2 Select [Peripheral Configuration] from the [Advanced] menu, and set the
following items.
Set [Serial 1] to [Disabled]
Set [Serial Multiplexer] to [iRMC]
3 Select [Saving Changes & Exit] in the [Exit] menu to exit the BIOS Setup Utility.