CS875-575-375-275-175 Installers Manual with CS5500 keypadB.13.7
13.4 Glossary
Location Term Definition
13 CS7002 GPRS Module A module that operates as a GPRS and GSM communications module for 
reporting and upload/download. 
13.1 Reporting A menu entry that groups reporting options.
13.1.1 Report Control A block of reporting data that contains configurations to format selected events 
into one or more messages according to pre-configured settings and send 
them to specified destinations.
A menu entry that groups report control options.
13.1.1.1.1 Destination A menu option that configures the report destination for the selected report 
control. 
13.1.1.1.2 Backup Destination A menu option that configures the backup destination for the selected report 
control. If using another device as the backup destination, set the reporting 
format in Reporting>Backup Format and enable test report events in the 
backup device. 
13.1.1.1.3 Events A menu entry that contains all configurable events for each report control. All 
events for report control 1 are enabled by default. Events for all other report 
controls are disabled by default. Enabled events are formatted into one or 
more messages according to pre-configured settings and sent to the selected 
report destination. You must enable only Test Reports if using the CS7002 as 
backup to another auxiliary dialler.
13.1.1.1.3.1 Arm/Disarm/Alarm A menu entry that groups the events that are reported to the selected report 
control. 
13.1.1.1.3.1.1 Alarms A menu option that sends a report to the selected report control when an alarm 
occurs. 
13.1.1.1.3.1.2 Alarm Restores A menu option that sends a report to the selected report control when the 
alarm has been restored after an alarm. 
13.1.1.1.3.1.3 Opening/Closings A menu option that sends a report to the selected report control stating when 
the system is opened (disarmed) and closed (armed).  
13.1.1.1.3.1.4 Zone Bypass and Restores A menu option that sends a report to the selected report control when a zone is 
bypassed. A report is also sent when the zone is restored (un-bypassed). 
13.1.1.1.3.2 Tamper/Trouble A menu entry that groups together the tamper and trouble events that are 
reported to the selected report control.
13.1.1.1.3.2.1 Tampers and Restores A menu option that sends a report to the selected report control when a tamper 
occurs. A report is also sent when the tamper is no longer active. 
13.1.1.1.3.2.2 Zone Trouble and Restores A menu option that sends a report to the selected report control when a zone 
trouble condition occurs. A report is also sent when the trouble condition is no 
longer active. 
13.1.1.1.3.2.3 Expander Trouble and Restores A menu option that sends an expander trouble and restore report to the 
selected report control.
13.1.1.1.3.2.4 Siren/Phone Faults and Restores A menu option that sends a report to the selected report control when a siren 
or phone fault occurs. A restore report is sent when the fault is fixed. 
13.1.1.1.3.2.5 RF Sensor Lost and Restores A menu option that sends a report to the selected report control when an RF 
sensor is missing. A restore report is sent to the central station when the 
receiver receives a valid signal from the lost transmitter. 
13.1.1.1.3.2.6 RF Low Battery and Restores A menu option that sends a report to the selected report control when a low 
battery condition occurs in an RF sensor. A restore report is also sent when the 
low battery condition is no longer active.