CS875-575-375-275-175 Installers Manual with CS5500 keypad B.2.4
2.3 Programming outputs
The control panel includes up to four on-board auxiliary outputs. CS507 output expander modules and CS320
power modules can be used to increase the number of outputs. For more information on the CS507 output
expander, see chapter 11. For information on the CS320 power module, see chapter 15.
To program on-board outputs, select Installer Menu>Control Panel>Outputs.
2.3.1 Configuring an output
You can change the characteristics of each output. You must specify the events and/or partitions that activate an
output and the length of time for which the output is activated. The events are grouped in the programming tree.
A full list of all possible selectable events can be found in Table 2-1: Control panel output events. The following
example configures output 1 to activate for 15 minutes when a burglary alarm occurs.
1. Navigate with the µ¶ keys to Control Panel>Outputs>Prog Outputs>Output 1 and press OK.
2. Scroll to Event>Alarms>Burglary Alarm and press OK.
3. The keypad beeps once to confirm the change and returns to Alarms.
4. Scroll to Time Unit>Minutes and press OK.
5. The keypad beeps once to confirm the change and returns to Time Unit.
6. Scroll to Time and press OK.
7. Select 15 min. and press OK to accept the changes.
8. The keypad beeps once to confirm the change and returns to Time.
1 (<Event>) Event Alarms
Arm/Disarm
Communications
Keypads
Sirens
Tamper/Trouble
Tests
Miscellaneous
2.2.1.1.1
2.2.1.1.1.1
2.2.1.1.1.8
2.2.1.1.1.7
2.2.1.1.1.6
2.2.1.1.1.5
2.2.1.1.1.4
2.2.1.1.1.3
2.2.1.1.1.2
Prog Outputs
2.2.1 2.2.1.1
Outputs 2 - 4
Same as above
Sounds On
Short Blast On
Output Signal Type
Sound On
Time Unit
Time
Partitions
Attributes
Phone Line Cut
Tampers
Expander Trouble
Arming
Exit Expiry
Closing Kissoff
Keyswitch Arming
Phone Line Cut
Mains Failure
Low Battery
B-Alarm Trip
Tampers
Expander Trouble
Latched
Code Stops Timer
Only if Closed
Only if Open
Inverted
When Armed
When Disarmed
When Armed
When Disarmed
2.2.1.1.2
2.2.1.1.5
2.2.1.1.4
2.2.1.1.3
2.2.2.1.1
2.2.2.2.1
2.2.2.2.4
2.2.2.2.3
2.2.2.2.2
2.2.3.1.1
2.2.3.1.6
2.2.3.1.5
2.2.3.1.4
2.2.3.1.3
2.2.3.1.2
2.2.3.1.1.1
2.2.1.1.5.1
2.2.1.1.5.5
2.2.1.1.5.4
2.2.1.1.5.3
2.2.1.1.5.2
2.2.2.1.1.1
2.2.2.1.3
2.2.2.1.2
2.2.2.1.1.2
2.2.3.1.1.2
Internal Siren
Keypads
2.2.2
2.2.3
2.2.2.1
2.2.2.2
2.2.2.3
2.2.3.1