EasyManuals Logo

GE Security CS575 User Manual

GE Security CS575
209 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #170 background imageLoading...
Page #170 background image
CS875-575-375-275-175 Installers Manual with CS5500 keypadB.15.5
10. Navigate with the µ¶ keys to Options>Reporting>Report Format and select the format relevant for your
central station receiver.
11. The keypad beeps once to accept the change and returns to Report Format.
12. Navigate with the µ¶ keys to E-mail Reporting>E-mail Server>Domain Name and press OK.
13. Enter the domain name of the server to which reports are sent and press OK.
14. The keypad beeps once to accept the change and returns to Domain Name.
15. Scroll to E-mail Server>IP Address and press OK.
16. Enter the IP address of the server to which reports are sent and press OK.
17. The keypad beeps once to accept the change and returns to IP Address.
15.3.3 Configuring reporting options
The CS7050 TCP/IP module can send primary, backup and dual reports. The following steps explain how to
configure each type of report.
1. Navigate with the µ¶ keys to CS7050 TCP/IP Module>Options>Reporting and press OK.
2. To use another CS7050 receiver as backup, select Receiver 2 as Backup>Enabled and press OK.
3. To use the control panel as backup:
- Select Control Panel is Backup>Enabled and press OK.
- Enable autotest report on the control panel phone events and panel system events.
- Ensure the reporting format used by the control panel is the same as that set in Report Format.
4. To configure dual reporting:
- Select Receiver 2 as Backup>Disabled and press OK.
- Select Control Panel is Backup>Disabled and press OK.
- Enable all event categories on the control panel.
15.3.4 Configuring upload/download
To enable upload/download, you must configure the session initiation settings on the CS7050 TCP/IP module and
specify the PC IP address and port. The upload/download access code is set on the control panel. The following
example enables download sessions during test calls. The calls are initiated from a central station (IP address
192.37.57.3) using the TCP/IP alarm port.
1. Navigate with the µ¶ keys to CS7050 TCP/IP Module>Up/Download and press OK.
2. Scroll to Remote Initiated>Enabled and press OK.
3. The keypad beeps once to accept the change and returns to Remote Initiated.
4. Scroll to IP Address and press OK.
5. Enter 192.37.57.3 and press OK.
6. The keypad beeps once to accept the change and returns to IP Address.
7. Scroll to Auto U/D at Test Time>Enabled and press OK.
8. The keypad beeps once to accept the change and returns to Auto U/D at Test Time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security CS575 and is the answer not in the manual?

GE Security CS575 Specifications

General IconGeneral
BrandGE Security
ModelCS575
CategorySecurity System
LanguageEnglish

Related product manuals