CS875-575-375-275-175 Installers Manual with CS5500 keypad B.2.10
6. The keypad beeps once to confirm the change and returns to Exit 1.
2.6.2 Configuring a partition
You can set partition features including arming and bypassing options. You can also enable life safety keys for
the partition keypads. The following example allows the system to be armed with a lost zone and enables the
personal alarm combination keys so they activate a personal attack alarm when pressed.
1. Ensure the advanced menu is enabled.
2. Navigate with the µ¶ keys to Control Panel>Partition Settings>Feature Select>Arming and press OK.
3. Scroll to Arming with Zone Lost>Yes and press OK.
4. The keypad beeps once to confirm the change and returns to Arming with Zone Lost.
5. Navigate with the µ¶ keys to Keypads>Silent PA (7+9)>Yes and press OK.
6. The keypad beeps once to confirm the change and returns to Silent PA (7+9).
<
When the Arming with Zone Lost option is enabled, the user is always allowed to arm the system even if the
PIR or door/window sensor does not report within the short window. For more information on short windows,
see chapter 9.
2.7 Configuring the system
Configurable system settings include timers, input features, the system clock and serial port and various tests that
can be performed on the control panel. To program system settings, select Installer Menu>Control
Panel>System Settings.
Sounders
Batt Dynamic Test Duration
Mains Report Delay
Power Up Delay
Inputs
Power
Communications
Internal Siren Timeout
External Siren Timeout
Chime Time
Phone Line Cut Delay
Inputs
On-board 8 zones
Box Tamper
2-wire Smoke Detectors
Force Default Zone Types
Batt Presence Test
Dynamic Batt Test at Armin