CS875-575-375-275-175 Installers Manual with CS5500 keypadB.2.9
2.5.4 Enabling reporting
You must enable event reporting in the control panel and program the events and zone types for which reports are
sent. You must specify the format of the report and, in the case of voice reports, you must map each event to a
recorded message. You can map one message to a number of events. The following example enables voice
reporting to phone number 2 for a phone line cut event and assigns a voice message to this event.
1. Navigate with the µ¶ keys to Control Panel>Communications>Central Station and press OK.
2. Scroll to Phone Numbers>Phone Number 2>Protocol>Voice and press OK.
3. The keypad beeps once to confirm the change and returns to Protocol.
4. Navigate with the µ¶ keys to Reporting>Report Codes>Communications and press OK.
5. Scroll to Phone Line Cut>Voice Channel and press OK.
6. Scroll to the number of the message that you want to map to that zone and press OK.
7. The keypad beeps once to confirm the change and returns to Voice Channel.
2.6 Configuring partitions
A partition is a group of zones which operate as a unit and can be armed and disarmed independently of other
partitions in the system. A partition is also known as an area. The control panel can be divided into separate
partitions with distinct zones, keypad and user codes for each partition. Arming and bypass options can be set for
each partition. To program partition settings, select Installer Menu>Control Panel>Partition Settings.
2.6.1 Setting timers
You can specify the time in which a user must disarm or arm a system before a full alarm occurs. The following
example sets time within which the user must leave the
protected zone after arming the system (12 seconds). It also
sets the time within which the user must disarm the system (10 seconds).
1. Navigate with the µ¶ keys to Control Panel>Partition Settings>Timers >Entry 1 and press OK.
2. Enter 12 and press OK.
3. The keypad beeps once to confirm the change and returns to Entry 1.
4. Scroll to Exit 1 and press OK.
5. Enter 10 and press OK.
Entry 1
Exit 1
Entry 2
Exit 2
Arming
Quick Arm
Re-exit
Silent Auto Arm
Silent Exit Always
Armin
g
with Zone Lost
Miscellaneous
Silent PA (7+9)
Audible PA (7+9)
Fire/Aux 1 (1+3)
Medical/Aux 2 (4+6)
Multi Code Tamper
LED Extinguish
Bypass Auto Bypass
Code Required
Sounder Alert
Bypass Toggle
Mains/Batt Sounder Alert
Zone Lost Gives Tamper
Timers
Feature Select
2.5.1
2.5.2
2.5.1.1
2.5.1.2
2.5.1.3
2.5.1.4
2.5.2.1
2.5.2.2
2.5.2.3
2.5.2.4
2.5.2.1.1
2.5.2.1.2
2.5.2.1.3
2.5.2.1.4
2.5.2.1.5
2.5.2.2.1
2.5.2.2.2
2.5.2.2.3
2.5.2.2.4
2.5.2.2.5
2.5.2.2.6
2.5.2.3.1
2.5.2.3.2
2.5.2.3.3
2.5.2.3.4
2.5.2.4.1
2.5.2.4.2
Keypads

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security CS575 and is the answer not in the manual?

GE Security CS575 Specifications

General IconGeneral
BrandGE Security
ModelCS575
CategorySecurity System
LanguageEnglish

Related product manuals