EasyManuals Logo

GE Datex-Ohmeda Aisys Carestation User Manual

GE Datex-Ohmeda Aisys Carestation
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #408 background imageLoading...
Page #408 background image
Aisys
10-52 04/08 M1046983
10.32 Tubing for use with Legris fittings (O
2
supplies)
This tubing is a flexible, Nylon-type tubing for use with quick-release fittings.
Item Description Length — Size Stock Number
1 unmarked 96 mm - 1/4 inch 1001-3064-000
2 unmarked 167 mm - 1/4 inch 1001-3064-000
3 unmarked (blue) 68 mm - 1/4 inch 1011-3905-000
Tube Markings (factory build only)
303 unmarked 200 mm - 6 mm 1001-3062-000
304 unmarked 150 mm - 6 mm 1001-3062-000
305 unmarked 110 mm - 6 mm 1001-3062-000
306 unmarked 120 mm - 6 mm 1001-3062-000
310 unmarked 310 mm - 6 mm 1001-3062-000
312ALT O2 FLOWMETER TEE 620 mm - 6 mm 1001-3062-000
313 unmarked 140 mm - 6 mm 1001-3062-000
320 unmarked 420 mm - 6 mm 1001-3062-000
325 unmarked 130 mm - 6 mm 1001-3062-000
326 unmarked 80 mm - 6 mm 1001-3062-000
329 unmarked (clear) 140 mm - 1/8 inch 0994-6370-010
337 unmarked 45 mm - 6 mm 1001-3062-000
338 unmarked 130 mm - 6 mm 1001-3062-000
341 A/SCGO FG VAP OUT 600 mm - 1/4 inch 1001-3064-000
342 SWITCH PORT 4 ALT O2 IN 500mm - 6 mm 1001-3062-000
343 MIXER OUT VAP IN 660 mm - 1/4 inch 1001-3064-000
344 unmarked 40 mm - 6 mm 1001-3062-000
345 unmarked 65 mm - 6 mm 1001-3062-000
346 unmarked 60 mm - 6 mm 1001-3062-000
349 unmarked 130 mm - 1/4 inch 1001-3064-000
350 unmarked 170 mm - 1/4 inch 1001-3064-000
353 unmarked 75 mm - 6 mm 1001-3062-000
*Refer to Section 10.31.
** These are current tubing connections to the eVap. Refer to Section 10.31 for original tubing
connections to the eVap.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Datex-Ohmeda Aisys Carestation and is the answer not in the manual?

GE Datex-Ohmeda Aisys Carestation Specifications

General IconGeneral
TypeAnesthesia Machine
ManufacturerGE Healthcare
ModelAisys Carestation
Power Requirements100-240V AC, 50/60 Hz
DisplayHigh-resolution color touchscreen
Ventilator TypeElectronically controlled ventilator
Ventilation ModesVolume Control, Pressure Control, SIMV, Pressure Support, Manual
Gas DeliveryOxygen, Nitrous Oxide, Medical Air
Power SupplyAC mains, Battery backup
Integrated MonitoringYes
CommunicationEthernet
ConnectivityEthernet
AlarmsComprehensive alarm system for ventilation, gas delivery, and patient monitoring parameters

Related product manuals