ADL300 • Functions description and parameters list 19
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.1.6 11028 Multi speed 4 Hz FLOAT 0.00 -10000 10000 RW FVS
Setting of the multispeed 4 value. Can be selected via digital input, eldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.1.7 11030 Multi speed 5 Hz FLOAT 0.00 -10000 10000 RW FVS
Setting of the multispeed 5 value. Can be selected via digital input, eldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.1.8 11032 Multi speed 6 Hz FLOAT 0.00 -10000 10000 RW FVS
Setting of the multispeed 6 value. Can be selected via digital input, eldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.1.9 11034 Multi speed 7 Hz FLOAT 0.00 -10000 10000 RW FVS
Setting of the multispeed 7 value. Can be selected via digital input, eldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.1.10 12010 Actual multi spd sel ENUM R FVS
The currently selected speed is displayed.
0 Multi speed 0
1 Multi speed 1
2 Multi speed 2
3 Multi speed 3
4 Multi speed 4
5 Multi speed 5
6 Multi speed 6
7 Multi speed 7
8 Null
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.1.11 12210 Actual speed ref m/s FLOAT R FVS
The speed of the cabin is displayed in m/s.