36 ADL300 • Functions description and parameters list
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.6.4 11284 Detection Limit PERC LONG 50 0 100 RW FVS
This is the current limit value delivered by the drive (expressed as a percentage of nominal current) to select the more
favorable riding direction in Recommended mode (see PAR 11262).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
5.6.5 12282 Chosen Direction INT 0 0 2 R FVS
Indicates the direction selected by the drive during the emergency.
0 No direction selected
1 Forward
2 Reverse
The association Forward/Reverse and Up/Down depends on how the connection to the motor was made.