96 ADL300 • Functions description and parameters list
sorg parameter in its menu.
When setting a parameter, the format is also automatically set in the sys parameter.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.3.2 4022 Fieldbus M->S1 sys ENUM Not assigned 0 10 ERW FVS
21.3.6 4032 Fieldbus M->S2 sys ENUM Not assigned 0 10 ERW FVS
21.3.10 4042 Fieldbus M->S3 sys ENUM Not assigned 0 10 ERW FVS
21.3.14 4052 Fieldbus M->S4 sys ENUM Not assigned 0 10 ERW FVS
21.3.18 4062 Fieldbus M->S5 sys ENUM Not assigned 0 10 ERW FVS
21.3.22 4072 Fieldbus M->S6 sys ENUM Not assigned 0 10 ERW FVS
21.3.26 4082 Fieldbus M->S7 sys ENUM Not assigned 0 10 ERW FVS
21.3.30 4092 Fieldbus M->S8 sys ENUM Not assigned 0 10 ERW FVS
21.3.34 4102 Fieldbus M->S9 sys ENUM Not assigned 0 10 ERW FVS
21.3.38 4112 Fieldbus M->S10 sys ENUM Not assigned 0 10 ERW FVS
21.3.42 4122 Fieldbus M->S11 sys ENUM Not assigned 0 10 ERW FVS
21.3.46 4132 Fieldbus M->S12 sys ENUM Not assigned 0 10 ERW FVS
21.3.50 4142 Fieldbus M->S13 sys ENUM Not assigned 0 10 ERW FVS
21.3.54 4152 Fieldbus M->S14 sys ENUM Not assigned 0 10 ERW FVS
21.3.58 4162 Fieldbus M->S15 sys ENUM Not assigned 0 10 ERW FVS
21.3.62 4172 Fieldbus M->S16 sys ENUM Not assigned 0 10 ERW FVS
Setting of the format of the datum received on the channel. When the src parameter is programmed, the format is auto-
matically programmed on the relative sys. If the src parameter is reset to null, the format does not change. The value of the
format can be selected from the following list, according to the parameter selected as the source:
0 Not assigned
1 Count 16
2 Count 32
3 Fill 16
4 Fill 32
5 Mdplc 16
6 Mdplc 32
7 UM
8 UM oat
9 Par 16
10 Par 32
If set to 0 the channel is not assigned.
If set to 1 the datum is assigned a 16-bit count.
If set to 2 the datum is assigned a 32-bit count.
If set to 3 16 bits on the channel are reserved for the datum, not used.
If set to 4 32 bits on the channel are reserved for the datum, not used.
If set to 5 the datum is assigned a 16-bit count used by MDPLC.
If set to 6 the datum is assigned a 32-bit count used by MDPLC.
If set to 7 the datum is assigned engineering units on a 16-bit integer.
If set to 8 the datum is assigned engineering units on a 32-bit integer.
If set to 9, the datum is assigned a 16-bit integer engineering unit format not in real time (5-10ms)
If set to 10 the datum is assigned a 32-bit integer engineering unit format or oat format if the associated parameter is a
oat-type parameter not in real time (5-10ms)
Note! If the sys parameter is not assigned, none of the subsequent fieldbus channels are read, even if programmed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
21.3.3 4024 Fieldbus M->S1 mon INT32 32BIT 0 0 0 ER FVS
21.3.7 4034 Fieldbus M->S2 mon INT32 32BIT 0 0 0 ER FVS
21.3.11 4044 Fieldbus M->S3 mon INT32 32BIT 0 0 0 ER FVS
21.3.15 4054 Fieldbus M->S4 mon INT32 32BIT 0 0 0 ER FVS
21.3.19 4064 Fieldbus M->S5 mon INT32 32BIT 0 0 0 ER FVS
21.3.23 4074 Fieldbus M->S6 mon INT32 32BIT 0 0 0 ER FVS
21.3.27 4084 Fieldbus M->S7 mon INT32 32BIT 0 0 0 ER FVS
21.3.31 4094 Fieldbus M->S8 mon INT32 32BIT 0 0 0 ER FVS