EasyManua.ls Logo

gefran TPD32-EV-500 series - Current Regulation (Current Regulat)

gefran TPD32-EV-500 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— TPD32-EV ——————
174
6.8 CURRENT REGULATION (CURRENT REGULAT)
Motoring&Generating Torque Limit
From Speed Regulator
To Droop Feedback
speed
torque
T current lim +
T current lim -
T current lim -
T current lim +
+1% of Motor nom speed-1%of Motor nom speed
Current Limits
Current regulator
Current regulator includes
anti-windup logic
+
-
speed
torque
T current lim +
T current lim -Tcurrent lim -
T current lim +
Torque
reduction
T
T
Torque reduction
command
Go to Motor
parameters
Modulator
DC
Motor
Feedback
(option)
Torque Limit +/-
T current lim +
150 %
T current lim -
150 %
T current lim
150 %
In use Tcur lim+
In use Tcur lim-
Current lim red
100 %
T current ref
Motor current
Curr limit state
T curr lim type
Torque reduct
Arm resistence
2.55 Ohm
Arm inductance
34.33 mH
Output voltage
Figure 6.8.1: Torque current regulaton
CURRENT REGULAT
[41] Tcurrentref[%]
[199] Motorcurrent[%]
[1430] Motcurthreshld[%]
[1431] Motcurthdelay[ms]
[1520] dI/dtdeltatime
[453]
Armresistance[
ohm]
[454] Arminductance[mH]
[587] Eint[V]
[452] R&LSearch
[353] Zerotorque
Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
T current ref [%]
41 -200 +200 - - **
Motor current [%]
199 -250 250 - - -
Mot cur threshld [%]
1430 0 200 100 100
Mot cur th delay [ms]
1431 0 65535 1000 1000
Arm resistance [ohm]
453 S S 0.500 0.500 -
Arm inductance [mH]
454 S S 4.00 4.00 -
E int [V]
587 -80 +80 - - **
R&L Search
OFF
ON
452 0 1 OFF OFF -
Zero torque
Active
Notactive
353 0 1 Notactive(1) Notactive(1) *
*Thisfunctioncanbeassignedtooneoftheprogrammabledigitalinputs.
** Thisparametercanbeassignedtoaprogrammableanalogoutput.
TheuserdenesthefullloadcurrentofthemotorviatheFull load curr(FLC)parameterintheCONFIGURA-