EasyManua.ls Logo

gefran TPD32-EV-500 series - Speed Limitation

gefran TPD32-EV-500 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— TPD32-EV ——————
362
Speed input var 1strampreferencevalue.Thevaluetobeenteredisbasedonthefactorfunction
Speed ref var 1stspeedreferencevalue.Thevaluetobeenteredisbasedonthefactorfunction
Act speed value Speedactualvalueintheunitspeciedinthefactorfunction.
Speed base value TheSpeed base valueisgivenintheunitspeciedinthefactorfunction.Itisthe
basevalueforallspeedvaluesgivenasapercentage(referencevalues,adaptivespeed
regulation...).Achangeinthisparameterisonlypossiblewhenthedriveisdisabled.
(Enable drive=Disabled).
Speed input perc 1strampreferencevalue.DenedasapercentageoftheSpeed base value
Percent ref var 1stspeedreferencevalue.DenedasapercentageoftheSpeed base value
Act percentage SpeedactualvalueasapercentageoftheSpeed base value
6.18.3 Speed limitation
DRIVECOM
Speed amount
[1] Speedminamount[FF]
[2] Speedmaxamount[FF]
Speed min/max
[5] Speedminpos[FF]
[3] Speedmaxpos[FF]
[6] Speedminneg[FF]
[4] Speedmaxneg[FF]
Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Speed min amount [FF]
1 0 2
32
-1 0 0
-
Speed max amount [FF]
2 0 2
32
-1 5000 5000
-
Speed min pos [FF]
5 0 2
32
-1 0 0
-
Speed max pos [FF]
3 0 2
32
-1 5000 5000
-
Speed min neg [FF]
6 0 2
32
-1 0 0
-
Speed max neg [FF]
4 0 2
32
-1 5000 5000
-
Speed min amount Denestheminimumspeedforbothrotationdirections(withTPD32-EV...4B...).
Alowervaluethanthedenedvalueisnotpossible,regardlessofthereferencevalue
set.Ithasaneffectontheinputoftheramp.IftheSpeed min amountparameteris
changed,theSpeed min pos andSpeed min neg parametersaresettothesamevalue.
Ifoneofthesetwoparametersischangedlater,thelastchangeisvalid.Thecurrent
valueforpositiverotation(clockwise)isshowninthedisplayofthekeypad.Thevalue
tobeenteredisbasedonthefactorfunction.
Speed max amount Denesthemaximumspeedforbothrotationdirections(withTPD32-EV...4B...).
Thefunctionhasaneffectontheinputofthespeedregulatorandthereforetakesinto
accountthereferencevaluethatcomesfromtherampaswellasthedirectlydened

Table of Contents

Related product manuals