—————— TPD32-EV ——————
208
6.12.1 Analog Ouputs
I/O CONFIG
Analog outputs
Analog output 1
[66] Selectoutput1
[62] Scaleoutput1
Analog output 2
[67] Selectoutput2
[63] Scaleoutput2
Analog output 3
[68] Selectoutput3
[64] Scaleoutput3
Analog output 4
[69] Selectoutput4
[65] Scaleoutput4
Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Select output 1
66 0 94 Actualspeed(8) Actualspeed(8)
Scale output 1
62 Float -10.000 +10.000 0.000 0.000
Select output 2
67 0 94 Motorcurrent(16) Motorcurrent(16)
Scale output 2
63 -10.000 +10000 0.000 0.000
Select output 3
68 0 94 Fluxcurrent(27) Fluxcurrent(27)
*
Scale output 3
64 -10.000 +10000 0.000 0.000
Select output 4
69 0 94 Outputvoltage(20) Outputvoltage(20)
*
Scale output 4
65 -10.000 +10000 0.000 0.000
* TBOoptioncard(TBO“B”)hastobeinstalled.
Select output XX Selectionoftheparameterassignedasavariabletothecorrespondinganalogoutput.
Thefollowingassignmentsarepossible:
OFF
Speed ref 1
1)
Speed ref 2
1)
Ramp ref 1
1)
Ramp ref 2
1)
Ramp ref
1)
Speed ref
1)
Ramp out
1)
Actual speed
1)
T current ref 1
2)
T current ref 2
2)
T current ref
2)
Speed reg out
2)
Motor current
2)
0
1
2
3
4
5
6
7
8
9
10
11
15
16
Output voltage
3)
Analog input 1
4)
Analog input 2
4)
Analog input 3
4)
Flux current
5)
Pad 0
6)
Pad 1
6)
Pad 4
6)
Pad 5
6)
Flux reference
7)
Pad 6
6)
PID output
8)
Out vlt level
3)
Flux current max
5)
20
24
25
26
27
31
32
33
34
35
38
39
79
80
F act spd
1)
F T curr
2)
Speed draw out
9)
Output power
10)
Roll diameter
Act tension ref
Torque current
W reference
Actual comp
Brake current
11)
Field cur ref
12)
Motor Pot Out
81
82
84
88
89
90
91
92
93
94
95
96
11)
OutputthatmonitorsthevalueoftheTorque provingparameter.
12)
Itindicatestheeldcurrentreference.
Scale output XX Scalingoftheanalogoutputconcerned
1)
Withascalingfactorof1theoutputsupplies10Vwhenthereferencevalueor
speedcorrespondstothevaluedenedbySpeed base value.
2)
Withascalingfactorof1,theanalogoutput=10Vwhenthereferenceorcurrent
is100%.
3)
Withascalingfactorof1theoutputsupplies10Vwhenthevoltagecorresponds

Table of Contents