—————— TPD32-EV ——————
494
AccessoriesforconnectingtheTPD32-EV/TPD32-EV-CUcontrolunitviaberopticstotheTPD32-EV-FC
externalexciter:
Code Description Remarks
S7QAE3
or
S7QAQ8
M/S cable Master/slave connection cable:
3 mt. = S7QAE3
5 mt. = S7QAQ8
S5H78 SBI-OFM-32 Master card
S5H83 SBI-OFS-32 Slave card
note: Theboardsandthe3-metercablearealreadyincludedintheTPD32-EV12Pulsecongura-
tion.Ifrequested,theTPD32-EV-FCmustbeusedviaastandardexternalI/Oconnection.
A2.5.1 Fiber optics connection of master board (in TPD32-EV-CU unit) to Slave board (in
TPD32-EV-FC unit)
Figure A2.5.1: Block diagram of Field exciter control, fiber optics connection
2Q / 4Q
R-TPD32
M
TPD32-EV-CU
Control Unit
TPD32-EV-FC
External Field
TPD32-EV-...-E
External Bridge
Optical fiber link
SBI-OFS-32
(Optional)
R-TPD32
SBI-OFM-32
(Optional)
Cable :
cod. S7QAE3 (3m)
cod. S7QAQ8 (5m)
2Q / 4Q
Externalconnectionsaremadewithconnectorswithdifferentnamesiftheboardisamaster(SBI-OFM-32)or
aslave(SBI-OFS-32).
Fortheserialcommunicationconnectionviaberopticsinterface,youhavetousetheoptionalcablespecied
above(3mor5m).
TX7
TX6
RX5
TX4
TX3
RX2
TX1
SBI-OFM-32
RX1
RX4
RX3
TX2
RX7
RX6
TX5
SBI-OFS-32
Cable cod. S7QAE3 (3 m)
Cable cod. S7QAQ8 (5 m)
SBI-OFM-32
TX1 RX2 TX3 TX4 RX5 TX6 TX7
RX1 RX2 RX3 RX4 RX5 RX6 RX7
SBI-OFS-32

Table of Contents