—————— TPD32-EV ——————
344
PROGRAMMING OF ANALOG INPUTS
ANALOGINPUT1
Tension ref Tensionreferencein%;10V(20mA)=100%
I/OCONFIGMenu
————>Analoginput
————>Analoginput1
————>Selectinput1 Tension ref:
ANALOGINPUT2 IftheparameterLine spd source hastobesetonananaloginput,asthisparameteris
notlistedamongthehighpriorityparameters,itisnecessarytopassthroughasupport
parameterPAD0…PAD15.
Line spd source:10V(20mA)=100%
Programmingoftheanaloginput2onPAD 0:
I/OCONFIGMenu
————>Analoginput
————>Analoginput2
————>Selectinput2=PAD0
ANALOGINPUT3 IftheparameterRef spd source hastobesetonananaloginput,asthisparameteris
notlistedamongthehighpriorityparameters,itisnecessarytopassthroughasupport
parameterPAD0…PAD15.
Ref spd source:10V(20mA)=100%
Programmingoftheanaloginput2onPAD 1:
I/OCONFIGMenu
————>Analoginput
————>Analoginput3
————>Selectinput3=PAD1
PROGRAMMING OF DIGITAL INPUTS
DIGITALINPUT1
Diam calc Dis: Disablingofthediametercalculation(seealsopar.Line speed thr).Incaseduringthe
functioningperioditistemporarilydisabled,thesystemstoresthelastcalculatedvalue.
Thisfunctionhastobeenabledonlyiftheapplicationrequiresit.
I/OCONFIGMenu
————>digitalinput
————>digitalinput1: Diam calc Dis:
DIGITALINPUT2
Wind/unwind Winder/unwinderselection.Incasetheselectioniscarriedoutviathedigitalinput:0V
=Winder,+24V=Unwinder.