EasyManua.ls Logo

gefran TPD32-EV-500 series - Page 482

gefran TPD32-EV-500 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— TPD32-EV ——————
482
Connection of current transducers and thermal switch(es)
ThesecondarywindingsofthetwoACcurrenttransducersandanythermalcircuitbreakers(bimetalthermostats)
onthepowerbridgesareconnectedtotheKPT31connector.Aspeciccablealreadyttedwiththerelative
KPT31connectorattheCUendandfreeconductorsattheotherendissupplied(“KPT31connectorinterface
cableforTPD32-EV-CU”,EAM2763).
Terminal Function Min. cable cross-section Max. cable cross section Tightening torque
1, 2, 3 * Connection of bimetal thermostats 0.25 mm
2
(24AWG) 2.5 mm
2
(12AWG) 0.5 …0,6Nm
5, 6, 7, 8 CT connection Recommended : 1 mm
2
(18AWG)
note ! IftheNCthermalcontact(bimetalthermostat)connectedbetweenterminals1and2isnot
used,thesemustbejumpered.Terminal3isalreadyjumperedinternallywithterminal2via
jumperS2ontheFIRXP-XXpowercard,asstandard.Terminal4isnotused.
Detailofconnectionofcurrenttransducers:
brown
blue
red
CT-U
CT-W
5678
KPT3
1
brown
brown
UWV
Twisted
wires
Twisted
wires
Connection of pulse transformers
TheprimarycircuitsofthepulsetransformersareconnectedtoconnectorKPT11(andKPT21,whereapplicable)
forswitchingtheSCRson.AspeciccablealreadyttedwiththerelativeKPT11connectorattheCUendand
freeconductorsattheotherendissupplied(“KP11connectorinterfacecableforTPD32-EV-CU”,EAM2764).
Fordetailsofwiring,seeESE5771showingtheconnectionofa4Qbridge(reversible).Witha2Qbridge,thetwo
conductorslabelled“MN”arenotused.Theirfreeendmustthereforenotbeconnectedbutelectricallyisolated.
Regulation power supply
AsfortheentireTPD32-EV-…series,theregulationpowersupplyisconnectedtoterminalsU2-V2onthe
FIRXP-XXpowercard.Toaccessthis,removetheplasticcoveratthebottom.
Thiscardalsocontainsterminals35-36,75-76and78-79whichhavethesamefunctiononallunitsintheTPD32-
EV-..seriesandhavealreadybeendescribedinchapter"4.4RegulationSection"onpage69.
Cablecross-sectionsandtighteningtorque
Terminal Function Min. cable cross-section Max. cable cross section Tightening torque
U2, V2 Regulation power supply
0.25 mm
2
(24AWG)
2.5 mm
2
(12AWG)
0.5 …0.6 Nm
35, 36 Contact OK Relay
75, 76 Relay 2 contact
78, 79 Motor thermistor

Table of Contents