CE7000-UM-251-9370 7-69
7 DISASSEMBLY AND REASSEMBLY
Conrming the exible cable wiring from the push roller sensor board to the Y relay board
The exible cable has a right side and a wrong side, connect the exible cable correctly as shown in the
picture below.
[Y relay board side]
CE7000-40/60
Y relay board
Conrm the printed side,
which is facing to the up.
Push roller sensor exible cable
Y relay board
Conrm the printed side,
which is facing to the front.
CE7000-130/130AP/60
[Push roller sensor board side]
Push roller sensor board
Push roller sensor exible cable
Conrm the printed side,
which is facing to the front.