CE7000-UM-251-9370 8-22
8 Electrical Adjustment
(9) Press the ENTER key to display the following menu.
Use the UP or DOWN position key to change the force setting.
(10) The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force as shown in the
picture below.
And measure the actual force when the bottom of blade holder leaves from the cutting mat. Don’t
measure the force that keep lifting the tool.
(11) Ifthemeasuredvalueisnotwithinthespecicationrange(10±2g),reduceorincreasetheD/Avalueto
bewithinthespecicationrange(10±2g).
(12) PresstheENTERkeywhenthemeasuredvalueiswithinthespecicationrange(10±2g).
(13) The48g-penforcespeciedpenforceadjustmentmenuappears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(14) Adjustthe40g-penforce.Ifthemeasuredvalueisnotwithinthespecicationrange(40±4g),reduceor
increasetheD/Avaluetobewithinthespecicationrange(40±4g).
(15) PresstheENTERkeywhenthemeasuredvalueiswithinthespecicationrange(40±4g).
(16) The120g-penforcespeciedpenforceadjustmentmenuappears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(17) Adjustthe120g-penforce.Ifthemeasuredvalueisnotwithinthespecicationrange(120±10g),reduce
orincreasetheD/Avaluetobewithinthespecicationrange(120±10g).
(18) PresstheENTERkeywhenthemeasuredvalueiswithinthespecicationrange(120±10g).
(19) The305g-penforcespeciedpenforceadjustmentmenuappears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(20) Adjustthe305g-penforce.Ifthemeasuredvalueisnotwithinthespecicationrange(305±10g),reduce
orincreasetheD/Avaluetobewithinthespecicationrange(305±10g).
(21) PresstheENTERkeywhenthemeasuredvalueiswithinthespecicationrange(210±10g).
(22) The458g-penforcespeciedpenforceadjustmentmenuappears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(23) Adjustthe458g-penforce.Ifthemeasuredvalueisnotwithinthespecicationrange(458±15g),reduce
orincreasetheD/Avaluetobewithinthespecicationrange(458±15g).