CE7000-UM-251-9370 8-23
8 Electrical Adjustment
(24) PresstheENTERkeywhenthemeasuredvalueiswithinthespecicationrange(458±15g).
Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changesthetemperatureoftheactuatorandcausesarticiallylowerreadings.Whenthis
happenstheactualpenforcemaybehigherthanthespecication.Thisisespeciallytrueforthe
upper pen force adjustment.
(25) The following menu is displayed.
(26) Turn off the power to exit from the adjustment menu. (When other adjustment is going to perform
continuously it does not need to turn off the power.)
Specication of the actual pen force
Speciedpenforce Actual force range
10g 8 to 12g
40g 36 to 44g
120g 110 to 130g
305g 295 to 315g
458g 443 to 563g