CE7000-UM-251-9370 8-28
8 Electrical Adjustment
(14) Press the ENTER key to set the value, then the following menu is displayed.
(15) Press the F3 key to display the following menu.
UP and down allow keys changes value
Slow key changes unit
(16) Input the Y-axis distance adjustment value by the actual measuring value of Y.
(If you measured the 249.0 mm for the Y-axis, input the 249.00.)
(17) Press the ENTER key to set the value, then the following menu is displayed.
(18) Press the F4 key to display the following menu.
UP and down allow keys changes value
Slow key changes unit
(19) Input the XY distance adjustment value by the actual measuring value of diagonal distance.
(If you measured the 352.0 mm for the diagonal distance, input the 352.00.)
(20) Press the ENTER key to set the value, then the following menu is displayed.
(21) LoadanA3orlargersizesheetofpaperintheplotter.
(22) Press the F4 key (ADJUSTED PATTERN) to start to draw the adjusted pattern.
(23) Takeoutthedrawnpatternofpaperfromtheplotter,andthenmeasurethedistancetoconrmthe
adjusted distance is 250 x 250 mm with right angle.
(24) Turn off the power to exit from the adjustment menu. (When other adjustment is going to perform
continuously it does not need to turn off the power.)