13 – 180 HEIDENHAIN Service Manual iTNC 530
„Pinging" If no TNCremoNT connection is established, check by pinging, whether the ...
Ethernet card in the laptop
Ethernet card in the control
Connection of both cards via Ethernet
... function properly.
"Ping-loopback-test" on the laptop (test of the Ethernet card of the laptop):
8 In the prompt enter the ping command followed a blank and the IP address of the Ethernet
card of the laptop (e.g. ping 160.1.178.23).
8 Confirm with ENTER. --> If the Ethernet card functions it will respond!
If the Ethernet card does not function, a timeout message is displayed.
"Ping-loopback-test" on the control (test of the Ethernet card of the control):
8 Enter the code number NET123, confirm with ENTER and subsequently press the PING soft
key.
8 Enter the IP address of the iTNC.
8 Confirm ENTER. -->If the Ethernet card functions, you receive the answer HOST RESPOND.
If the Ethernet card does not function, the TIMEOUT message is displayed.
Pinging from the laptop to the control (test of the connection):
8 In the prompt enter the ping command followed by a blank and the IP address of the control.
8 Press ENTER to confirm. --> If the connection works, the control will respond!
If the Ethernet card does not function, a timeout message is displayed.
Figure: Pinging from the laptop to the control successful
Note
If the following error message is displayed during connection establishment, …
... the external access to the control is not permitted!
In this case press the MOD key and subsequently theEXTERNAL ACCESS ON/OFF soft key
in order to permit access.