4 – 34 HEIDENHAIN Service Manual iTNC 530
8B20 Error <axis>
field orientation
Field orientation impossible for mechanical
reasons.
Incorrect relation between electrical field
and mechanical motor motion.
Incorrect motor encoder signal.
Incorrect motor connection.
Mechanical brakes not released.
Check the machine parameters for number
of signal periods and distance for the
number of signal periods.
Check the machine parameter for the linear
distance of one motor revolution.
For linear motors: check column STR of the
motor table.
Check the speed encoder connection.
Check the motor connection.
Release brakes during orientation.
See “Speed Encoders” on page 18 – 293. See “Sequence for Finding Errors in the
Control Loop” on page 6 – 62.
See “Speed Encoders” on page 18 – 293.
See Service Manual Inverter Systems and
Motors.
8B30 Motor
temperature
%.2s too high
Measured motor temperature is too high.
No temperature sensor
Motor encoder cable is defective (wire
broken).
Entry in motor table is incorrect.
Incorrect or defective temperature sensor
was installed.
Let the motor cool down.
Check the motor encoder cable.
Check the entry in the motor table.
Measure the temperature sensor (576
[Ohm] at 20 [°C]).
See “Speed Encoders” on page 18 – 293.
See Service Manual Inverter Systems and
Motors.
See “Speed Encoders” on page 18 – 293.
See Service Manual Inverter Systems and
Motors.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions in
the manual
Additional information and descriptions in
the manual