July 2010 4 – 35
8B40 No drive
enabling %.2s
Inverter is not ready for operation.
No pulse release for the power module.
Uz too high
Power-fail signal is active.
With M controls: I32 input inactive
With P controls: Drive release at X50
inactive
In addition, for 246 261-xx (digital current
controller):
For the given axis an illegal motor model
(e.g. linear motor) was selected.
The CC receives a "Drive on" command for a
nonexistent axis.
The power module is not ready when the
field orientation starts.
Readiness of the power module is detected
through the Ready signal on the PWM cable.
The power module is not ready when the
current controller adjustment begins.
Motor control board defective
PWM cable defective
Noise pulses
Check the activation and wiring of the pulse
release.
Check Uz.
Check the emergency stop circuit.
For a non-regenerative system: Is the
braking resistor connected?
For a regenerative system: Is the energy
recovery activated?
Check the grounding and shielding of the
cable.
Exchange the power module.
For SIEMENS power converter (inverter):
Exchange the interface card.
Exchange drive control board.
Check the control and cabling of the pulse
release.
See “Checking the Enables on the iTNC
530” on page 16 – 229.
See Service Manual Inverter Systems and
Motors.
8B50 Axis module
%.2s not ready
No pulse release for the power module
Uz too high
5-V power supply too weak
Inverter not ready for operation
Motor control board defective
PWM cable defective
Noise pulses
Check the control and cabling of the pulse
release.
Check Uz.
If the power supply is not regenerative: Is
the braking resistor connected?
If the power supply is regenerative: Is the
energy recovery activated?
Check the grounding and shielding of the
cable.
Exchang
e the power module.
For P controls: Exchange the interface card.
Exchange
the motor drive control board.
See “Checking the Enables on the iTNC
530” on page 16 – 229.
See Service Manual Inverter Systems and
Motors.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions in
the manual
Additional information and descriptions in
the manual