EasyManua.ls Logo

HEIDENHAIN ITNC 530 - Page 459

HEIDENHAIN ITNC 530
696 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2010 27 – 459
X8:
Analog output
1 to 6
D-sub connector, 15-pin
X9:
Analog output
7 to 13
D-sub connector, 15-pin
There is no connector X9 on the MC 422 C.
MC 42x (B/C) Connecting cable
Female Pin layout Male Color
1 Analog output 1: ±10 V 1 Brown
2 Do not assign 2 Brown/Green
3 Analog output 2: ±10 V 3 Yellow
4 Analog output 5: ±10 V 4 Red/Blue
5 Analog output 3: ±10 V 5 Pink
6 Analog output 5: 0 V 6 GY/PK
7 Analog output 4: ±10 V 7 Red
8 Analog output 6: ±10 V 8 Violet
9 Analog output 1: 0 V 9 White
10 Do not assign 10 WH/GY
11 Analog output 2: 0 V 11 Green
12 Do not assign 12
13 Analog output 3: 0 V 13 Gray
14 Analog output 4: 0 V 14 Blue
15 Analog output 6: 0 V 15 Black
Housing External shield Housing External shld.
MC 42x (B) Connecting cables
Female Pin layout Male Color
1 Analog output 7: ±10 V 1 Brown
2 Analog output 13
a
: ±10 V
a. Only for MC 422 B, but not for MC 422
2 Brown/Green
3 Analog output 8: ±10 V 3 Yellow
4 Analog output 11: ±10 V 4 Red/Blue
5 Analog output 9: ±10 V 5 Pink
6 Analog output 11: 0 V 6 GY/PK
7 Analog output 10: ±10 V 7 Red
8 Analog output 12: ±10 V 8 Violet
9 Analog output 7: 0 V 9 White
10 Analog output 13
a
: 0 V 10 WH/GY
11 Analog output 8: 0 V 11 Green
12 Do not assign 12
13 Analog output 9: 0 V 13 Gray
14 Analog output 10: 0 V 14 Blue
15 Analog output 12: 0 V 15 Black
Housing External shield Housing External shld.
Note
X8, X9: The interface complies with the requirements of EN 61800-5-1 for "protective extra-
low voltage" (PELV).
DANGER
X8, X9: Only units that comply with the requirements of EN 61800-5-1 for "protective extra-
low voltage" (PELV) may be connected.