July 2010 28 – 539
Adapting the
MPNAME.MP
Only necessary if you want to transfer the backup files by means of Ethernet interface
and the NC software version of the control is lower than 340420-08!
If the file MPNAME.MP is now displayed on the screen:
8 Press END to restart the control.
Setting date and
time on the control
8 Check the date and time of the control and reset it, if necessary. --> See “Setting the System
Time” on page 12 – 159.
Setting up the data
interface
8 Make the settings for Ethernet transmission on the control.
--> See “Via Ethernet” on page 13 – 172.
Subsequently, protect the IP4.N00 file to make sure it is not overwritten!
8 Or define the settings for the RS 232 interface.
--> See “Via serial interface RS-232-C or RS-422” on page 13 – 182.
Defining the NC
software version
8 Check the currently active NC software version. --> See “Display of Important System
Information” on page 26 – 443.
If you need another software version, it must be loaded now. --> Contact the machine
manufacturer!
Restoring the data As you could probably not store data from the defective hard disk, you must now go back to
available archives (PLC-data, TNC-data) to restore data on the new hard disk; if required, the
machine manufacturer can also provide you with PLC or machine data.
8 Establish a connection between your laptop and the control.
--> See “Connection Setup” on page 13 – 172.
8 Load the backup on the new hard disk of the MC 422.
--> See “Restoring Data” on page 13 – 197.
Note
If entries for additional control-loop indexes are now required in the machine parameter list
(error message MP: not defined) or there seem to be too many control-loop indexes (error
message MP: incorrect number), then ...
Delete the MPNAME.MP. -->
An adapted MPNAME.MP is generated automatically.
Press END. -->
The control boots and generates the Power interrupt message.
Note
As of NC software version 340420-08, the code number NET 123 for setting up the Ethernet
configuration is also accepted with open MP list.
Note
Delete the blue check mark for READ_MP.A in the LST file.
Background:
To each NC software version belongs a READ_MP.A file which includes the comments on the
current machine parameters (to be found under PLC:\JH\READ_MP.A). As the replacement
drives are normally supplied with the latest NC software version, the READ_MP.A in your
backup file possibly belongs to an older NC software version. If you have deleted the check
mark in your LST file, the current READ_MP.A is not overwritten by the old READ_MP.A.
It is not recommended to protect the READ_MP.A file on the control as otherwise the file
cannot be updated during an NC software update!