28 – 540 HEIDENHAIN Service Manual iTNC 530
Figure: Check mark with READ_MP.A has been removed
Updating the
machine
parameter list
If the control opens the machine parameter list after you have restored the back up, new
machine parameters are added with the current NC software of the replacement hard disk or
older MPs are removed.
8 Press the END key.
The following messages may be generated:
8 Enter a value for the new machine parameter.
8 The parameter is not required. --> Delete this MP or mark the parameter as comment so it
remains in the machine parameter list.
8 After each change, try to activate the machine parameter list with END.
If the MP list is complete, the iTNC 530 restarts.
Comments on the new MPs can be found in the text file READ_MP.A or READ_MP.A in path
PLC:\JH\ ...
Contact the machine manufacturer for more information!
If required you can add comments on the function of the new parameters in the MP list.