MP1200 Selection of the nominal position value filter used
Input: 0: Single filter
1: Double filter
2: HSC filter
3: Advanced HSC filter
340 490-01
PLC
RUN
MP1201 Nominal position value filter in manual operation
Input: 0: Single filter
1: Double filter
340 490-01
PLC
RUN
MP1202 Predefined tolerance for Cycle 32
Input: 0.0000 to 3.0000 [mm]
340 490-01
PLC
RUN
MP1202.0 Tolerance at corners for movements at machining feed rate
MP1202.1 Tolerance at corners for movements at rapid traverse
MP1205 Reduction of the contouring feed rate at the beginning of a contour element
Input: 0: Not active (fast, possibly less precise)
1: Active (slow but likely more precise)
340 490-03
MP1210 Limit frequency for single filter
Input: 0: Filter is switched off
0.0 to 166.0 [Hz]
340 490-01
PLC
MP1211 Limit frequency for double filter
Input: 0: Filter is switched off
0.0 to 166.0 [Hz]
340 490-01
PLC
MP1212 Limit frequency for HSC filter
Input: 0: Filter is switched off
0.0 to 166.0 [Hz]
340 490-01
PLC
MP1213 Limit frequency for advanced HSC filter
Input: 0: Filter is switched off
0.0 to 166.0 [Hz]
340 490-01
PLC
MP1222 Tolerance for curvature changes with HSC filter (only effective if MP7684 bit 4 = 0)
Entry: 0: Do not include the tolerance
1: Include the tolerance
340 490-01
PLC
RUN
MP1223 Tolerance for curvature changes with advanced HSC filter (only effective if MP7684 bit
4 = 0)
Entry: 0: Do not include the tolerance
1: Include the tolerance
340 490-01
PLC
RUN
MP1230.x Max. permissible axis-specific jerk at corners for single filter
Input: 0.1 to 1000.0 [m/s³]
340 490-01
PLC
RUN
MP1231.x Max. permissible axis-specific jerk at corners for double filter
Input: 0.1 to 1000.0 [m/s³]
340 490-01
PLC
RUN
MP1232.x Max. permissible axis-specific jerk at corners for HSC filter
Input: 0.1 to 1000.0 [m/s³]
340 490-01
PLC
RUN
MP1233.x Max. permissible axis-specific jerk at corners for advanced HSC filter
Input: 0.1 to 1000.0 [m/s³]
340 490-01
PLC
RUN
MP Function and input SW version